20kv electrical wire/20kv cable/20kv electric cable
Product Description
Â
Â
20kv electrical wire/20kv cable/20kv electric cable
Â
APPLICATIONS
Predominantly used for primary underground distribution in conduit systems; suitable for use in wet or dry locations, direct burial, underground
duct, and where exposed to sunlight. The engineered Power polyethylene jacket allows the cable to slide through duct with less friction, resulting
in longer pulls or longer pushes with less lubricant, or in some cases, no lubricant at all. To be used at 15,000 volts or less and at conductor
temperatures not to exceed 90°C for normal operation.
Â
STANDARDS
15kV Power MV Primary UD Cable meets or exceeds the following ASTM specifications:
•     B3  Soft Annealed Copper Wire
•     B8  Concentric-Lay-Stranded Copper Conductors, Hard, Medium-Hard or Soft
•     B230      Aluminum, 1350-H19 Wire for Electrical Purposes
•     B231      Aluminum 1350 Conductors, Concentric-Lay-Stranded
•     B609      Aluminum 1350 Round Wire, Annealed and Intermediate Tempers, for Electrical Purposes
Â
15kV Power MV Primary UD Cable is manufactured to the latest edition of the following specifications, and in case of specification conflicts, in the
order listed:
•     ANSI/ICEA S-94-649
•     AEIC CS-8
•     RUS U-1
Â
Â
CONSTRUCTION
The cable is composed of a solid or moisture blocked reverse lay, compressed stranded soft drawn copper, or a solid or moisture blocked reverse
lay or unilay compressed stranded 1350-H16/26 aluminum phase conductor, covered by a semi-conducting cross-linked polyethylene strand
shield, a tree-retardant cross-linked polyethylene primary insulation, and a semi-conducting cross-linked polyethylene insulation shield.
Conductors are available with either 100% or 133% insulation levels. A concentric neutral of bare copper wires and a sunlight resistant, -40°C
rated, insulating engineered Power polyethylene jacket are applied over the insulation shield. The cable is identified by surface print on the jacket
and with the lightning bolt symbol for supply cables indented in the jacket. Red extruded stripes available upon request. A semi-conducting
engineered Power polyethylene jacket is also available upon request.
Â
TECHNICAL PARAMETER LIST
Â
Phase Conductor |
Neutral |
Thickness Per Cond. (mils) |
Diameter (mils) |
Weight 1000 feet (lbs.) |
Allowable Ampacities+ |
||||||||
Size (AWG or kcmil) |
Strand- ing |
No. of Wires |
Size (AWG) |
Nominal Insul. |
Insul. Shield min. Point |
Approx. Jkt. |
 Bare Phase Cond. |
Over Insul. |
 Over Insul. Shield |
Comp. Cable |
Comp. Cable |
Direct Burial |
In Ducts |
ALUMINUM CONDUCTOR - 100% INSULATION LEVEL | |||||||||||||
2 |
Solid |
10 |
14 |
175 |
30 |
50 |
258 |
653 |
733 |
961 |
453 |
168* |
119* |
2 |
7 |
10 |
14 |
175 |
30 |
50 |
283 |
678 |
758 |
986 |
470 |
168* |
119* |
1 |
Solid |
13 |
14 |
175 |
30 |
50 |
289 |
685 |
765 |
993 |
520 |
193* |
137* |
1 |
19 |
13 |
14 |
175 |
30 |
50 |
322 |
718 |
798 |
1026 |
539 |
193* |
137* |
1/0 |
Solid |
16 |
14 |
175 |
30 |
50 |
325 |
720 |
800 |
1028 |
591 |
218* |
155* |
1/0 |
19 |
16 |
14 |
175 |
30 |
50 |
352 |
748 |
828 |
1056 |
609 |
218* |
155* |
2/0 |
19 |
20 |
14 |
175 |
30 |
50 |
395 |
790 |
870 |
1098 |
703 |
248* |
177* |
3/0 |
19 |
25 |
14 |
175 |
30 |
50 |
443 |
838 |
918 |
1146 |
817 |
284* |
201* |
4/0 |
19 |
20 |
12 |
175 |
30 |
50 |
498 |
893 |
973 |
1234 |
993 |
324* |
230* |
 250 |
37 |
16 |
10 |
175 |
30 |
50 |
558 |
963 |
1043 |
1346 |
1213 |
360* |
257* |
350 |
37 |
18 |
14 |
175 |
40 |
50 |
661 |
1068 |
1168 |
1396 |
1055 |
389** |
319** |
500 |
37 |
25 |
14 |
175 |
40 |
50 |
789 |
1193 |
1293 |
1521 |
1349 |
468** |
384** |
750 |
61 |
24 |
12 |
175 |
40 |
80 |
968 |
1383 |
1483 |
1798 |
1946 |
569** |
468** |
1000 |
61 |
20 |
10 |
175 |
40 |
80 |
1117 |
1530 |
1630 |
1988 |
2473 |
642** |
542** |
1250 |
91 |
25 |
10 |
220 |
55 |
80 |
1250 |
1765 |
1895 |
2253 |
3142 |
688** |
604** |
1500 |
91 |
30 |
10 |
220 |
55 |
80 |
1370 |
1885 |
2015 |
2373 |
3616 |
726** |
637** |
COPPER CONDUCTOR - 100% INSULATION LEVEL | |||||||||||||
2 |
Solid |
16 |
14 |
175 |
30 |
50 |
258 |
653 |
733 |
961 |
664 |
210* |
150* |
2 |
7 |
16 |
14 |
175 |
30 |
50 |
283 |
678 |
758 |
986 |
684 |
210* |
150* |
1 |
Solid |
20 |
14 |
175 |
30 |
50 |
289 |
685 |
765 |
993 |
780 |
240* |
171* |
1 |
19 |
20 |
14 |
175 |
30 |
50 |
322 |
718 |
798 |
1026 |
803 |
240* |
171* |
1/0 |
Solid |
25 |
14 |
175 |
30 |
50 |
325 |
720 |
800 |
1028 |
922 |
273* |
194* |
1/0 |
19 |
25 |
14 |
175 |
30 |
50 |
362 |
758 |
838 |
1066 |
951 |
273* |
194* |
2/0 |
19 |
20 |
12 |
175 |
30 |
50 |
405 |
800 |
880 |
1142 |
1161 |
313* |
224* |
3/0 |
19 |
25 |
12 |
175 |
30 |
50 |
456 |
853 |
933 |
1194 |
1390 |
358* |
255* |
4/0 |
19 |
20 |
10 |
175 |
30 |
50 |
512 |
908 |
988 |
1291 |
1717 |
410* |
293* |
250 |
37 |
24 |
10 |
175 |
30 |
50 |
558 |
963 |
1043 |
1346 |
1992 |
446* |
322* |
350 |
37 |
18 |
12 |
175 |
40 |
50 |
661 |
1068 |
1168 |
1429 |
1964 |
489** |
400** |
500 |
37 |
26 |
12 |
175 |
40 |
50 |
789 |
1193 |
1293 |
1554 |
2651 |
577** |
472** |
750 |
61 |
25 |
10 |
175 |
40 |
80 |
968 |
1383 |
1483 |
1840 |
3906 |
649** |
532** |
1000 |
61 |
26 |
9 |
175 |
40 |
80 |
1117 |
1530 |
1630 |
2013 |
5041 |
720** |
630** |
1250 |
91 |
26 |
8 |
175 |
55 |
80 |
1250 |
1765 |
1895 |
2306 |
6400 |
760** |
667** |
+  Ampacities shown assume use of 100% load factor, 60 Hz current, 36" burial depth, 20°C ambient temperature, 90°C conductor temperature, earth RHO 90, insulation and shield RHO 400 *  Full neutral construction (Ampacities assume - single phase circuit, one cable) ** 1/3 neutral cable (Ampacities assume - three phase circuit, 3 cables triplexed, multi-point grounding per ICEA methods) |
Â
Company Information
Â
Contact:
Â
Â
20kv electrical wire/20kv cable/20kv electric cable
Product Description
Â
Â
20kv electrical wire/20kv cable/20kv electric cable
Â
APPLICATIONS
Predominantly used for primary underground distribution in conduit systems; suitable for use in wet or dry locations, direct burial, underground
duct, and where exposed to sunlight. The engineered Power polyethylene jacket allows the cable to slide through duct with less friction, resulting
in longer pulls or longer pushes with less lubricant, or in some cases, no lubricant at all. To be used at 15,000 volts or less and at conductor
temperatures not to exceed 90°C for normal operation.
Â
STANDARDS
15kV Power MV Primary UD Cable meets or exceeds the following ASTM specifications:
•     B3  Soft Annealed Copper Wire
•     B8  Concentric-Lay-Stranded Copper Conductors, Hard, Medium-Hard or Soft
•     B230      Aluminum, 1350-H19 Wire for Electrical Purposes
•     B231      Aluminum 1350 Conductors, Concentric-Lay-Stranded
•     B609      Aluminum 1350 Round Wire, Annealed and Intermediate Tempers, for Electrical Purposes
Â
15kV Power MV Primary UD Cable is manufactured to the latest edition of the following specifications, and in case of specification conflicts, in the
order listed:
•     ANSI/ICEA S-94-649
•     AEIC CS-8
•     RUS U-1
Â
Â
CONSTRUCTION
The cable is composed of a solid or moisture blocked reverse lay, compressed stranded soft drawn copper, or a solid or moisture blocked reverse
lay or unilay compressed stranded 1350-H16/26 aluminum phase conductor, covered by a semi-conducting cross-linked polyethylene strand
shield, a tree-retardant cross-linked polyethylene primary insulation, and a semi-conducting cross-linked polyethylene insulation shield.
Conductors are available with either 100% or 133% insulation levels. A concentric neutral of bare copper wires and a sunlight resistant, -40°C
rated, insulating engineered Power polyethylene jacket are applied over the insulation shield. The cable is identified by surface print on the jacket
and with the lightning bolt symbol for supply cables indented in the jacket. Red extruded stripes available upon request. A semi-conducting
engineered Power polyethylene jacket is also available upon request.
Â
TECHNICAL PARAMETER LIST
Â
Phase Conductor |
Neutral |
Thickness Per Cond. (mils) |
Diameter (mils) |
Weight 1000 feet (lbs.) |
Allowable Ampacities+ |
||||||||
Size (AWG or kcmil) |
Strand- ing |
No. of Wires |
Size (AWG) |
Nominal Insul. |
Insul. Shield min. Point |
Approx. Jkt. |
 Bare Phase Cond. |
Over Insul. |
 Over Insul. Shield |
Comp. Cable |
Comp. Cable |
Direct Burial |
In Ducts |
ALUMINUM CONDUCTOR - 100% INSULATION LEVEL | |||||||||||||
2 |
Solid |
10 |
14 |
175 |
30 |
50 |
258 |
653 |
733 |
961 |
453 |
168* |
119* |
2 |
7 |
10 |
14 |
175 |
30 |
50 |
283 |
678 |
758 |
986 |
470 |
168* |
119* |
1 |
Solid |
13 |
14 |
175 |
30 |
50 |
289 |
685 |
765 |
993 |
520 |
193* |
137* |
1 |
19 |
13 |
14 |
175 |
30 |
50 |
322 |
718 |
798 |
1026 |
539 |
193* |
137* |
1/0 |
Solid |
16 |
14 |
175 |
30 |
50 |
325 |
720 |
800 |
1028 |
591 |
218* |
155* |
1/0 |
19 |
16 |
14 |
175 |
30 |
50 |
352 |
748 |
828 |
1056 |
609 |
218* |
155* |
2/0 |
19 |
20 |
14 |
175 |
30 |
50 |
395 |
790 |
870 |
1098 |
703 |
248* |
177* |
3/0 |
19 |
25 |
14 |
175 |
30 |
50 |
443 |
838 |
918 |
1146 |
817 |
284* |
201* |
4/0 |
19 |
20 |
12 |
175 |
30 |
50 |
498 |
893 |
973 |
1234 |
993 |
324* |
230* |
 250 |
37 |
16 |
10 |
175 |
30 |
50 |
558 |
963 |
1043 |
1346 |
1213 |
360* |
257* |
350 |
37 |
18 |
14 |
175 |
40 |
50 |
661 |
1068 |
1168 |
1396 |
1055 |
389** |
319** |
500 |
37 |
25 |
14 |
175 |
40 |
50 |
789 |
1193 |
1293 |
1521 |
1349 |
468** |
384** |
750 |
61 |
24 |
12 |
175 |
40 |
80 |
968 |
1383 |
1483 |
1798 |
1946 |
569** |
468** |
1000 |
61 |
20 |
10 |
175 |
40 |
80 |
1117 |
1530 |
1630 |
1988 |
2473 |
642** |
542** |
1250 |
91 |
25 |
10 |
220 |
55 |
80 |
1250 |
1765 |
1895 |
2253 |
3142 |
688** |
604** |
1500 |
91 |
30 |
10 |
220 |
55 |
80 |
1370 |
1885 |
2015 |
2373 |
3616 |
726** |
637** |
COPPER CONDUCTOR - 100% INSULATION LEVEL | |||||||||||||
2 |
Solid |
16 |
14 |
175 |
30 |
50 |
258 |
653 |
733 |
961 |
664 |
210* |
150* |
2 |
7 |
16 |
14 |
175 |
30 |
50 |
283 |
678 |
758 |
986 |
684 |
210* |
150* |
1 |
Solid |
20 |
14 |
175 |
30 |
50 |
289 |
685 |
765 |
993 |
780 |
240* |
171* |
1 |
19 |
20 |
14 |
175 |
30 |
50 |
322 |
718 |
798 |
1026 |
803 |
240* |
171* |
1/0 |
Solid |
25 |
14 |
175 |
30 |
50 |
325 |
720 |
800 |
1028 |
922 |
273* |
194* |
1/0 |
19 |
25 |
14 |
175 |
30 |
50 |
362 |
758 |
838 |
1066 |
951 |
273* |
194* |
2/0 |
19 |
20 |
12 |
175 |
30 |
50 |
405 |
800 |
880 |
1142 |
1161 |
313* |
224* |
3/0 |
19 |
25 |
12 |
175 |
30 |
50 |
456 |
853 |
933 |
1194 |
1390 |
358* |
255* |
4/0 |
19 |
20 |
10 |
175 |
30 |
50 |
512 |
908 |
988 |
1291 |
1717 |
410* |
293* |
250 |
37 |
24 |
10 |
175 |
30 |
50 |
558 |
963 |
1043 |
1346 |
1992 |
446* |
322* |
350 |
37 |
18 |
12 |
175 |
40 |
50 |
661 |
1068 |
1168 |
1429 |
1964 |
489** |
400** |
500 |
37 |
26 |
12 |
175 |
40 |
50 |
789 |
1193 |
1293 |
1554 |
2651 |
577** |
472** |
750 |
61 |
25 |
10 |
175 |
40 |
80 |
968 |
1383 |
1483 |
1840 |
3906 |
649** |
532** |
1000 |
61 |
26 |
9 |
175 |
40 |
80 |
1117 |
1530 |
1630 |
2013 |
5041 |
720** |
630** |
1250 |
91 |
26 |
8 |
175 |
55 |
80 |
1250 |
1765 |
1895 |
2306 |
6400 |
760** |
667** |
+  Ampacities shown assume use of 100% load factor, 60 Hz current, 36" burial depth, 20°C ambient temperature, 90°C conductor temperature, earth RHO 90, insulation and shield RHO 400 *  Full neutral construction (Ampacities assume - single phase circuit, one cable) ** 1/3 neutral cable (Ampacities assume - three phase circuit, 3 cables triplexed, multi-point grounding per ICEA methods) |
Â
Company Information
Â
Contact:
Â
Â
Magnetic USB Cable refers to the magnet male and female to suction mode to connect the charging effect of the charging cable. Rely on the magnet magnetic attraction, traditional cable connector is separated from the cable body, both through magnetic in automatic adsorption within a certain distance, so called magnetic suction cable magnetic suction cable, magnetic suction cable, magnetic suction charging cable, etc.so that we can realize single hand plug cable, and in the process of actual use, the magnetic suction charging cable is safer than ordinary USB Cable.
Interface widely applicable to mainstream models.Thin small size for wide, differs from the traditional life of the common data interface,a new type of magnetic suction cable charging interface on the size of the thin body, even mobile phones with a set of use, magnetic suction cable also apply to the charging 90% of cell phone sets, don't need to pick a set can be used directly, so it is suitable for use in the increasingly miniaturization of electronic equipment, Can withstand more than 50,000 times of repeated insertion and removal. Fast transmission speed, perfectly compatible with mobile phone data transmission.
It is easy to use,can be single-hand operation,regardless of positive and negative, random insertion, the error rate is zero, even if the 3-year-old children can not be inserted wrong, very suitable for driving, sleeping and other life scenarios. The appearance of magnetic charging cable has impacted the market of Usb C Cable, because magnetic charging cable is much better than ordinary data cable, bringing too much convenience to life. The feeling of user experience has also risen, and more people begin to enjoy the sense of convenience brought by magnetic charging cable to life.
Magnetic Usb Cable,5A Usb Cable,Magnetic Micro Usb Cable,Led Magnetic Charging Cable
Henan Yijiao Trading Co., Ltd , https://www.yjusbcable.com