The typical distribution box is equipped with a solid case that is capable of protecting the interior components from various adverse conditions, such as excessive exposure to heat or cold. The wiring and other parts that are contained in the box are usually mounted within the interior, helping to lessen the potential for the components to be damaged during any type of shifting that would otherwise create some type of abrasive action on wire coverings and other elements.
The distribution box made of ABS, PC,have good quality and good price.
Waterproof Distribution Box, Outdoor Distribution Box, Distribution Box NINGBO YULIANG TELECOM MUNICATIONS EQUIPMENT CO.,LTD. , https://www.yltelecom.com
Characteristics of Cable
1.Max Long-time operating temperature of PVC insulated cable is 70°C,XLPE 90°C
2.Installing temperature of cable should not be less than 0°C
3.Max short-circuit temperature is:PVC not exceed 160°C,XLPE 250°C,Not more than5 Sec.
4.Permitting bending radius cable: Not less than 10 DÂ times (D:external diameter of cable)
5.Perfect chemical stability, resistant against acids, alkali, grease and organic solvents, and flamer retardant
Â
1Core  Â
(sqmm)2CoreÂ
(sqmm)3coreÂ
(sqmm)3c+1c  Â
(sqmm)4core   Â
 (sqmm)3c+2c Â
 (sqmm)4c+1c    Â
(sqmm)5core Â
 (sqmm)
1x1.5
2x1.5
3x1.5
3x2.5+1x1.5
4x1.5
3x2.5+2x1.5
43x2.5+1x1.5
5x1.5
1x2.5
2x2.5
3x2.5
3x4+1x2.5
4x2.5
3x4+2x2.5
4x4+1x2.5
5x2.5
1x4
2x4
3x4
3x6+1x4
4x4
3x6+2x4
4x6+1x4
5x4
1x6
2x6
3x6
3x10+1x6
4x6
3x10+2x6
4x10+1x6
5x6
1x10
2x10
3x10
3x16+1x6
4x10
3x16+2x6
4x16+1x6
5x10
1x16
2x16
3x16
3x25+1x10
4x16
3x25+2x10
4x25+1x10
5x16
1x25
2x25
3x25
3x35+1x10
4x25
3x35+2x10
4x35+1x10
5x25
1x35
2x35
3x35
3x50+1x16
4x35
3x50+2x16
4x50+1x16
5x35
1x50
2x50
3x50
3x70+1x25
4x50
3x70+2x25
4x70+1x25
5x50
1x70
2x70
3x70
3x95+1x35
4x70
3x95+2x35
4x95+1x35
5x70
1x95
2x95
3x95
3x120+1x35
4x95
3x120+2x35
4x120+1x35
5x95
1x120
2x120
3x120
3x150+1x50
4x120
3x150+2x50
4x150+1x50
5x120
1x150
2x150
3x150
3x185+1x50
4x150
3x185+2x50
4x185+1x50
5x150
1x185
2x185
3x185
3x240+1x70
4x185
3x240+2x70
4x240+1x70
5x185
1x240
2x240
3x240
3x300+1x95
4x240
3x300+2x95
4x300+1x95
-
1x300
2x300
3x300
3x400+1x150
4x300
3x400+2x150
4x400+1x150
-
1x400
2x400
3x400
-
4x400
-
-
-Â
Cross Section of Conductor
No. of Wires
Thickness of Insulation
Thickness of Inner Sheath
Thickness of Steel Tape
No./Dia. Of Steel Wires
Thickness of Sheath
Overall Diameter
Approx. Net Weight
STA
SWA
STA
SWA
STA
SWA
STA
SWA
Al Conductor
Cu Conductor
Al Conductor
Cu Conductor
mm2
-
mm
mm
mm
No./mm
mm
mm
mm
mm
kg/km
kg/km
kg/km
kg/km
Three Cores
3x35
16
1.2
1
0.2
38/1.6
1.8
1.9
24.7
28.2
912
1591
1447
2126
3x50
18
1.4
1
0.2
46/1.6
1.9
2
29.3
32.8
1202
2105
1842
2745
3x70
18
1.4
1.2
0.2
41/2.0
2.0
2.2
32.5
37.1
1520
2820
2475
3775
3x95
36
1.6
1.2
0.5
46/2.0
2.1
2.3
36.5
40.8
2241
4049
2989
4797
3x120
36
1.6
1.2
0.5
50/2.0
2.2
2.4
39.8
44.1
2617
4895
3435
5713
3x150
36
1.8
1.2
0.5
43/2.5
2.3
2.5
42.4
47.8
3019
5846
4258
7085
3x185
36
2
1.4
0.5
50/2.5
2.5
2.7
48.8
54.2
3783
7264
5219
8700
3x240
60
2.2
1.6
0.5
58/2.5
2.8
2.9
56
61.3
4790
9390
6444
11044
3x300
60
2.4
1.6
0.5
61/2.5
2.9
3.1
59.3
64.7
5594
11345
7458
13209
Four Cores with Reduced Neutral
3x35+16
16-7
1.2-1
1
0.2
43/1.6
1.9
2
28.5
31.3
1107
1528
1705
2469
3x50+25
18-16
1.4-1.2
1.2
0.2
40/2.0
2.0
2.1
32.2
36.1
1410
2044
2326
3388
3x70+35
18-16
1.4-1.2
1.2
0.2
44/2.0
2.0
2.2
35.2
39.3
1733
2801
2762
4285
3x95+50
36-18
1.6-1.4
1.2
0.5
41/2.5
2.3
2.5
42.5
46.3
2656
3820
3816
5925
3x120+70
36-18
1.6-1.4
1.4
0.5
45/2.5
2.4
2.6
45.6
49.4
3137
4777
4391
7103
3x150+70
36-18
1.8-1.4
1.4
0.5
49/2.5
2.6
2.7
49.9
53.6
3660
5709
5043
8272
3x185+95
36-36
2-1.6
1.4
0.5
55/2.5
2.6
2.9
54.5
58.5
3445
7171
5902
9987
3x240+120
60-36
2.2-1.6
1.6
0.5
62/2.5
2.9
3.1
61.6
65.3
5441
9272
7174
12552
3x300+150
60-36
1.4-1.8
1.6
0.5
67/2.5
3.8
3.2
65.9
69.6
6494
11546
8355
15067
Four Cores
4x25
16
1.2
1
0.2
38/1.6
1.8
1.9
25.3
28
934
1576
1450
2092
4x35
16
1.2
1
0.2
41/1.6
1.8
1.9
27.4
30.2
1120
2017
1681
2578
4x50
18
1.4
1
0.2
39/2.0
2
2.1
31.6
35.6
1454
2658
2336
3540
4x70
18
1.4
1.2
0.5
43/2.0
2.1
2.2
36.3
39
2183
3916
2840
4573
4x95
36
1.6
1.2
0.5
50/2.0
2.3
2.4
40.6
44.1
2748
5160
3545
5957
4x120
36
1.6
1.4
0.5
42/2.5
2.4
2.5
43.9
47.2
3237
6214
4334
7372
4x150
36
1.8
1.4
0.5
48/2.5
2.5
2.6
48.3
52
3853
7622
5148
8917
4x185
36Distribution Box
We have a lot of Distribution Point Box,including 1pair drop wire box,4pair STB module box,10pair Distribution Point Box,20pair DP box.What's more,we can provide you 10pair pouyet DP box.
Model NO.: power cable
Material Shape: Round Wire
Range of Application: Flame Retardant
Certification: ISO9001, CE, CCC
Brand: Rmjt
Product Name: 600/1000V XLPE/PVC Insulation Power CableÂ
Type of Company: Manufacturer
Number of Wire: 1, 2, 3, 4, 5, 2+1, 3+2 or as Your Demand
Related Voltage: 0.6/1kv; 8.7/15kv; 12/20kv; 21/35kv; 26/35kv
Product Model: VV, Vlv, Yjv, Yjlv, Yjv22, Yjlv22, Yjv32, Yjlv32..
Standard: GB-T12706-2008; IEC 60502
Package: Wooden Drum, Steel Drum or as Your Requirement
Country of Origin: Professional Manufacturer of 25 Years in China
Advantages: High Quality, Competitive Price, Fast Delivery
Trademark: RMJT
Transport Package: Wooden/Steel Drum
Specification: 1.5mm2-800mm2
Origin: Henan, China
HS Code: 8544492100
Model NO.: power cable
Material Shape: Round Wire
Range of Application: Flame Retardant
Certification: ISO9001, CE, CCC
Brand: Rmjt
Product Name: 600/1000V XLPE/PVC Insulation Power CableÂ
Type of Company: Manufacturer
Number of Wire: 1, 2, 3, 4, 5, 2+1, 3+2 or as Your Demand
Related Voltage: 0.6/1kv; 8.7/15kv; 12/20kv; 21/35kv; 26/35kv
Product Model: VV, Vlv, Yjv, Yjlv, Yjv22, Yjlv22, Yjv32, Yjlv32..
Standard: GB-T12706-2008; IEC 60502
Package: Wooden Drum, Steel Drum or as Your Requirement
Country of Origin: Professional Manufacturer of 25 Years in China
Advantages: High Quality, Competitive Price, Fast Delivery
Trademark: RMJT
Transport Package: Wooden/Steel Drum
Specification: 1.5mm2-800mm2
Origin: Henan, China
HS Code: 8544492100
600/1000V XLPE/PVC Insulation Power CableÂ