50-240 Laid in indoor, tunnel, and trench pipes, cannot withstand mechanical external forces VV22

VLV22 copper core, aluminum core PVC insulated poly steel tape armored PVC sheathed power vv22 cable 4-240

50-240 With VV type, can be buried directly in the soil can withstand mechanical forces, can not withstand large pull ZRVV

ZRVLV copper core, aluminum core PVC insulated PVC sheathed flame retardant power zrvv cable 1-240

50-240 Same type VV, suitable for flame retardant applications ZRVV22

ZRVLV22 Copper core, aluminum core PVC insulated steel tape armored PVC sheathed flame-retardant power cable 4-240

50-240 Same as VV22 for NHVV-A with flame retardant requirements

NHVV-B copper core PVC insulated PVC sheathed fire resistant power vhvv cable 10-240

50-240 Same type as VV, suitable for fire resistant occasion NHVV22-A

NHVV22-B copper core PVC insulated steel tape armored PVC sheathed fire resistant power cable 10-240

50-240 Same type as VV22, suitable for occasions with fire resistant requirements Rated voltage 0.6/1kV Low voltage cross-linked polyethylene insulated power cable Product description Low voltage cross-linked cable products according to GB/T12706-2002 "rated voltage 1kV to 3kV Extrusion Insulation Power The cable "standard production, but also according to user needs according to standard production.

Model name Main use Copper core aluminum core YJV YJLV Cross-linked polyethylene insulated PVC sheathed power cable laid in indoor, tunnels, cable trenches and pipelines, can also be buried in loose soil, the cable can withstand a certain laying traction YJV 22 YJLV 22 cross-linked polyethylene insulated steel tape armored PVC sheathed power cable is suitable for indoor, tunnel, cable trench and underground buried laying, the cable can withstand mechanical external force, but can not withstand large tensile force YJV 32 YJLV 32 Cross-linked polyethylene insulated thin steel wire armored PVC sheathed power cable is suitable for high drop zone, the cable can withstand mechanical force and considerable pull force 1, use:

Low-voltage cable is suitable for fixed laying on transmission and distribution lines with AC 50Hz and rated voltage of 3kV and below for transmission of electrical energy.

2, the use of features:

1 The highest rated temperature of the cable conductor is 90°C.

2 The maximum temperature of the cable conductor does not exceed 250°C in the event of a short circuit (maximum duration not exceeding 5 seconds).

Torque Sensor

Torque Sensor,Torque Transducer,Rotary Torque Sensor,Torsion Sensor

GALOCE (XI'AN) M&C TECHNOLOGY CO., LTD. , https://www.galoce-meas.com

Posted on