Model NO.: AL/XLPE/CTS/HDPE
Wire Core Material: Aluminium
Certification: CCC, CE
Model: N2X
Brand: Jl
Rated Voltage: 6/10kv,18/30 Kv,8.7/15kv,3.6/6kv
Refer Standard: IEC60502-2
Trademark: JL
Transport Package: Wooden Drum/Steel Drum
Specification: 50-240 mm2
Origin: Jiangsu, China
HS Code: 76149000
Model NO.: AL/XLPE/CTS/HDPE
Wire Core Material: Aluminium
Certification: CCC, CE
Model: N2X
Brand: Jl
Rated Voltage: 6/10kv,18/30 Kv,8.7/15kv,3.6/6kv
Refer Standard: IEC60502-2
Trademark: JL
Transport Package: Wooden Drum/Steel Drum
Specification: 50-240 mm2
Origin: Jiangsu, China
HS Code: 76149000
Medium Voltage Aerial Bundled Conductor ABC Cables


Medium Voltage Aerial Bundled Conductor ABC Cables Standards:
IEC 60502 / AS/NZS 3599-1 standards
Medium Voltage Aerial Bundled Conductor ABC Cables Constructions:
Medium Voltage Aerial Bundled Conductor ABC Cables


Conductor: Round, Aluminium Conductor
Conductor Screen: Extruded semi-conductive layer.
Insulation:  XLPE
insulation Screen: Extruded semi-conductive layer.
metallic Screen(optional): Copper wire screen or copper tape screen.
Separator: Semi-conductive swellable tape.
outer Sheath: HDPE.
Messager wire: Galvanized steel wires.
Assembly: Three XLPE insulated screened cores are bundled around the galvanized steel
wires in a right hand lay.

MV Aerial Bundled Conductor ABC Cables Application:
Aerial bundled cables are mainly used for secondary overhead lines on poles or as feeders
to residential premises.
The Function of messenger wire:
A) It acts as load bearing wire.    B) It acts as earth or neutral conductor
MV Aerial Bundled Conductor ABC Cables Specifications:
IEC 60502 6/10 kV MV Aerial Bundled Conductor ABC Cables
Number of CoresxNominal Cross Section Phase Conductor Messenger Suspension Unit Continuous current rating at 30 ambient temp
Stranding Nominal Sectional Area Maximum Conductor Resistance Stranding Nominal Sectional Area Breaking Load
No.×mm2 No.×mm mm2 Ω/Km No.×mm mm2 KN A
3X50 + 1X25 19/1.78 50 0.641 7/3.0 50 60 116
3X70 + 1X50 19/.14 70 0.443 7/3.15 50 62 210
3X95+ 1X50 19/2.52 95 0.32 7/3.0 50 60 173
3X185+1X120 37/2.52 185 0.164 7/4.67 120 150 259
3X150 +1X50 37/2.25 150 0.206 7/3.15 50 62 365
3X240 +1X50 61/2.25 240 0.125 7/3.15 50 62 500
IEC 60502 18/30 kV MV Aerial Bundled Conductor ABC Cables
 
Number of CoresxNominal Cross Section Phase Conductor Messenger Suspension Unit Continuous current rating at 30 ambient temp
Stranding Nominal Sectional Area Maximum Conductor Resistance Stranding Nominal Sectional Area Breaking Load
No.×mm2 No.×mm mm2 Ω/Km No.×mm mm2 KN A
3X50 + 1X50 19/1.78 50 0.641 7/3.0 50 60 165
3X150+ 1X50 37/2.25 150 0.206 7/3.0 50 60 315
3X185+1X70 37/2.52 185 0.164 7/3.57 70 91 355
3X70 +1X50 19/2.14 7 0.443 7/3.15 50 62 250
3X150 +1X50 37/2.25 150 0.206 7/3.15 50 62 370

Medium Voltage Aerial Bundled Conductor ABC Cables
Medium Voltage Aerial Bundled Conductor ABC Cables
Medium Voltage Aerial Bundled Conductor ABC Cables

Medium Voltage Aerial Bundled Conductor ABC Cables



 
Medium Voltage Aerial Bundled Conductor ABC Cables


Medium Voltage Aerial Bundled Conductor ABC Cables Standards:
IEC 60502 / AS/NZS 3599-1 standards
Medium Voltage Aerial Bundled Conductor ABC Cables Constructions:
Medium Voltage Aerial Bundled Conductor ABC Cables


Conductor: Round, Aluminium Conductor
Conductor Screen: Extruded semi-conductive layer.
Insulation:  XLPE
insulation Screen: Extruded semi-conductive layer.
metallic Screen(optional): Copper wire screen or copper tape screen.
Separator: Semi-conductive swellable tape.
outer Sheath: HDPE.
Messager wire: Galvanized steel wires.
Assembly: Three XLPE insulated screened cores are bundled around the galvanized steel
wires in a right hand lay.

MV Aerial Bundled Conductor ABC Cables Application:
Aerial bundled cables are mainly used for secondary overhead lines on poles or as feeders
to residential premises.
The Function of messenger wire:
A) It acts as load bearing wire.    B) It acts as earth or neutral conductor
MV Aerial Bundled Conductor ABC Cables Specifications:
IEC 60502 6/10 kV MV Aerial Bundled Conductor ABC Cables
Number of CoresxNominal Cross Section Phase Conductor Messenger Suspension Unit Continuous current rating at 30 ambient temp
Stranding Nominal Sectional Area Maximum Conductor Resistance Stranding Nominal Sectional Area Breaking Load
No.×mm2 No.×mm mm2 Ω/Km No.×mm mm2 KN A
3X50 + 1X25 19/1.78 50 0.641 7/3.0 50 60 116
3X70 + 1X50 19/.14 70 0.443 7/3.15 50 62 210
3X95+ 1X50 19/2.52 95 0.32 7/3.0 50 60 173
3X185+1X120 37/2.52 185 0.164 7/4.67 120 150 259
3X150 +1X50 37/2.25 150 0.206 7/3.15 50 62 365
3X240 +1X50 61/2.25 240 0.125 7/3.15 50 62 500
IEC 60502 18/30 kV MV Aerial Bundled Conductor ABC Cables
 
Number of CoresxNominal Cross Section Phase Conductor Messenger Suspension Unit Continuous current rating at 30 ambient temp
Stranding Nominal Sectional Area Maximum Conductor Resistance Stranding Nominal Sectional Area Breaking Load
No.×mm2 No.×mm mm2 Ω/Km No.×mm mm2 KN A
3X50 + 1X50 19/1.78 50 0.641 7/3.0 50 60 165
3X150+ 1X50 37/2.25 150 Medical Device Wire

Medical Device Wire :The key requirements of modern medical connector include safety, reliability, small size and high speed performance. Since it is a small component in the overall design of any medical device, it can be considered that the connector is an important part of the medical equipment.

Common BV, RV line series

Silicone rubber insulated high temperature wire agr

High temperature braided wire AgRP with silicone rubber insulation and glass fiber

Silica gel high temperature control cable

Silicone rubber high voltage line agg 1kv-100kv

Teflon high voltage line 1kv-100kv

PFA Teflon insulated wire

FEP fluoroplastic high temperature line

PTFE fluoroplastic high temperature line

High temperature resistant control cable with Fluoroplastic insulation and sheath

Fire resistant and flame retardant control cable with PVC insulation sheath

Fire resistant line gn500 degree

Medical Device Wire

ShenZhen Antenk Electronics Co,Ltd , https://www.antenkwire.com

Posted on